-40%

Particle Measuring Systems PMS CLS-700 T Chemical Liquid Particle Counter

$ 3959.99

Availability: 100 in stock
  • Type: Corrosive Liquid Sampler
  • Model: CLS-700 T
  • Condition: The unit was Intel surplus and removed from a cart. It powers up and the status light flashes on and off (the green light). It does not provide any errors. It seems to be in functioning condition. There are various scratches on the plastic. It is sold as-is.
  • MPN: CLS-700 T
  • Particle Counter Type: Portable
  • Brand: Particle Measuring Systems
  • All returns accepted: ReturnsNotAccepted

    Description

    Particle Measuring Systems CLS-700 T Corrosive Liquid Particle Counter / Sampler
    Comes with what you see in the pictures. If you don't see it, you probably wont get it.
    Specifications are from Particle Measuring Systems and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    The unit was Intel surplus and removed from a cart. It powers up and the status light flashes on and off (the green light). It does not provide any errors. It seems to be in functioning condition. There are various scratches on the plastic. It is sold as-is.
    List Price is:
    ,700.00 to ,500.00 from Particle Measuring Systems
    The Unit's Serial Number Tag Reads:
    Model Number:
    CLS-700-(1)
    Serial Number:
    33185-0395-75
    Power Requirements:
    85 - 125 VAC, 50/60 Hz, 1.5 A
    Sensor Type:
    Liquilaz SO2 HF NO 99
    Description:
    The CLS-700 T corrosive liquid sampler is a compression sampler combined with a LiQuilaz liquid particle counter for effective measurement of particles in fluids contained in unpressurized vessels. It is ideally suited for testing effervescent chemicals. The system eliminates bubbles by pressurizing the sample and forcing the bubbles into solution.
    The CLS-700 T corrosive liquid sampler can be integrated into a wet bench for continuous particle monitoring, or located on a cart for increased mobility. When integrated into the wet bench, the sampling system can be started or stopped by the tool, including automatic shut-off during a bath change, to prevent the injection of chemical foam or air into the particle counter. The CLS-700 T corrosive liquid sampler is fully compliant with SEMI C1 for particle measurement of process chemicals.
    Benefits:
    Cost Reduction:
    50 or 80 mL/min. flow rate and 100% view volume means quicker process qualification
    Real-time characterization and analysis for immediate response to anomalies means less waste
    Versatility:
    Supports a wide range of applications and fluids
    Programmable particle-size thresholds
    Designed for easy mobility
    Compression sampling allows instrument to measure most chemicals, including effervescent ones
    External trigger coordinates sampling with process events
    Measurements can be made directly out of the bath
    Easy to Use:
    Facility Net process control software simplifies online sampling by providing alphanumeric paging, sensor status, tabular and SPC charts, and time plots
    SamplerSight batch sampling software facilitates all aspects of data management, including sophisticated data storage, retrieval, and report generation
    Designed for quick cleanup when switching from one chemical to another
    Applications:
    Particle level measurement in effervescent liquids
    Wet process monitoring
    Chemical process control
    Bath monitoring
    Main Specifications:
    Burette Volume:
    65 mL nominal
    Assessed Volume:
    48 mL nominal
    Maximum Compression Pressure:
    60 psi at 120°C or less; max. 45 psi at 150°C
    Exterior Surface:
    Polypropylene (Meets flame retardant specification FM4910.)
    Wetted Surface Materials:
    Kalrez 4079, Teflon, Kel-F (See LiQuilaz particle counter information for other wetted surfaces.)
    Sample Temperature:
    10 - 150°C at 45 psi or less (maximum 120°C at 60 psi); Sulfuric acid 100°C maximum
    Dimensions:
    16" L x 10" W x 16" H (41 cm x 26 cm x 39 cm)
    Weight:
    34 lbs. (15.5 kg.)
    Communications:
    RS-232 or RS-485
    Environment:
    Temperature:
    10 - 35°C
    Humidity:
    non-condensing
    Software:
    SampleSight, Facility Net (provided by the factory)
    Sampling:
    Optionally controlled via external trigger
    Factory Requirements:
    Power:
    See sensor requirements.
    Gas Pressure:
    70 - 150 psi
    Liquid Connections:
    Flaretek 1/4"
    Sensor Specifications:
    Size Range:
    0.2 - 2.0 µm
    Channels:
    15
    Flow Rate:
    50 mL/min. ±10%
    Sample Volume:
    Volumetric 50 mL/min. (100%)
    Maximum Concentration:
    10,000 particles/mL
    Sample Temperature:
    10 - 150°C (max. 150°C at 45 psi, 120°C at 60 psi); Sulfuric acid 100°C max.
    Maximum Pressure:
    100 psi
    Zero Count:
    < 1 count/mL
    Wetted Surface Materials:
    Sapphire, Teflon, Kel-F, Kalrez 4079
    Laser Source:
    Laser diode
    Dimensions:
    13" L x 4" W x 5" H (32 x 11 x 11 cm); mounts inside the CLS-700 T
    Weight:
    6 lbs. (2.7 kg)
    Power:
    85 - 132 V or 220 - 240 V, 50/60 Hz
    Communications:
    RS-485
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    05/26/09