-40%
CW-HPC600A Handheld Laser Particle Counter 6-Channels Dust Analyzer Auto Printer
$ 1098
- Description
- Size Guide
Description
templateCW-HPC600A Handheld Laser Particle Counter 6-Channels Dust Analyzer Auto Printer
Description:
CW-HPC600(A) handheld optical particle counter utilizes the laser technology for single particle detection. The scattering of light from the particles in the sampling air steam is converted into electrical pulses, which is then measured and calculated as a particle size.
The HPC600(A) consists of a handheld set with a main base unit that allows users to conduct the sampling around with a handheld set while easily expanding to multiple functionalities with a base unit. These extended functions include data downloading, data real-time printing, software upgrading, and battery charging, etc.
The HPC600(A) Particle count data is displayed as Concentration mode (Counts/Liter).
The HPC600(A) can also include a digital temperature and relative humidity probe, backlit interface and is capable of storing 1000 sample records. It is in compliance with the international standards (JIS B 9925:1997 and ISO14644-1) and support both metric and English systems.
Features:
• User configurable for all six size channels
• Auto print function
• Set and display date and time
• High speed USB interface for data downloading
• Up to 1000 sets of data can be stored
• Timer, auto-start sampling
• Average of multiple times of measurements
• External digital temperature and humility sensors to assure accurate measurement
• Support both
English and Chinese languages display
• No less than 6 hours of continuous operation
• Count Limit Warning: Setting according to the FED standard 209E or ISO 14644-1 standard
• Error status indicator: The instrument will automatically monitor the sensor status, out of flow calibration (>±5%), or insufficient battery
Specification:
• Test Range: 0.3μm~25μm
• Channel: Six channels
• Light Source: Laser diode (more than 100,000 hours MTBF)
• Coincidence Loss: <5% 70,000 particles/Liter
• Counting Efficiency: 50±5% 0.3μm; 100±10% 0.5μm
• Test Standard: JIS-B-9921 (1997), ASTM-F649-01, ASTM-F328-98 (NIST traceable)
• Sampling Time: 1 sec ~ 59 min and 59sec (User defined)
• Sampling Count: 1 ~ 99 (User defined)
• Count Limit Warning: FED STD 209E (Class 1 ~ 100,000) or ISO 14644-1 (Class 2 ~9)
• Measurement: Single/repeat/Average
• Error Indication: Count limit, loss of laser power, out of flow calibration (>±5%),insufficient battery
•Interface: USB, RJ45, RS232
• Communication Speed: USB —12Mbps
• Power: Li-ion polymer rechargeable battery (7.4V/2800mAH) or AC adapter (AC input:100 ~ 240V, DC output: 9V/1.5A)
• Max. Operating time: continue operation > 6 hours with Li-ion polymer battery)
• Operating temperature: 5~ 45℃; <90%RH
• Dimension: 93 (W) ×185 (H) × 48 (D) mm
• Weight: about 1kg
• Storage temperature: -20~ 60℃; <90%RH
• Standard configuration: AC adapter, Drive disc (enclosed specification), Portable protection case, Isokinetic sampling head
• Optional parts: Temperature and humidity sensor
What's in Package:
1x CW-HPC600A Laser Particle Counter
1.Your valid phone number is very necessary for the shipping, otherwise we can't guarantee that the package would safely arrives.
2. Any Customs tax applied to this package should be covered by buyers.
Contact Us:
1. We have always been trying to provide the best service and reliable products for every customer, however, accident may happen sometimes, please contact us to resolve any issue before leaving a negative feedback.
2. Please contact us by "Ask a question".
Payment
1. Payment methods accepted :
Paypal
only
.
2. Payment must be received within 7 business days of auction closing.
Shipping
1. We ship your orders within 1-2 business days after the payment received.
2. Item shipped via Singapore Post or HongKong Post , It takes about 7-14 business days (USA,CA,AU,UK). others country 10-20 business days(Brzil,India,RU), Exact delivery time depends on postal process.
3. If you do not receive your item(s) by 30 business days, Please feel free to contact us via ebay mail system , we will try our very best to resolve any problems with you
Return Policy
1. Return is accepted within 14 days after the buyer's receiving the item.
2. If this item is defective upon receipt, customer has up to 14 days from date of receipt for exchange of a new one.
3. Unused/unopened merchandise will be fully credited.
Other Policies
We are not responsible for any custom duty or import tax.
Any customs duty applied to the parcel should be covered by the buyer.
As has been stated on the eBay item description, Import duties, taxes and charges are not included in the item price and shipping charges.
These charges be at the buyer responsibility. meanwhile the customs tax depend on the buyer local customs office.
If you need we write low price on shipping bill, pls leave message when you make payment .
All emails will be answered within 24 hours. If you do not receive our reply, please kindly re-sent your email and we will reply to you as soon as possible, Suggest send eBay message to us, That is easy to find .