-40%
Anesthesia Machine S6100 PLUS 10.4 LCD Screen ( no US Shipping)
$ 13200
- Description
- Size Guide
Description
Anesthesia Machine S6100 PLUS 10.4 LCD Screen. Condition is "New".S6100 Plus Anesthesia System
Friendly Powerful Reliable
Application:
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Department and other departments. From high to low acuity, simple to complex cases, pediatric to geriatric patients, Superstar Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what’s more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based on High Security, High Accuracy, High Stability and accurate monitoring.
Trust Points
l Simplicity: easy to use, easy to move with 4 wheels.
l Choice: adapt the equipment to your patients and procedures freely
l Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes, including 5 modes: IPPV; A/C; PCV; SIMV; SIGH, MAUN.
l Designed and manufactured by Superstar Medical with over 23 years experience in this area.
l Flexible configurations to suit your needs.
l International standard and advanced technology suitable for wide range use.
l Compact interface and touch screen give you better operating experience.
l Over 2,000 units installed in the world.
Features
l 10.4” TFT LCD touch screen displays the Ventilation parameters, Alarming information and Waveform.
l Electronic flow meter, instantly know the fresh gas flow to your patient.
l Integration breathing circuit design, ensure easy operating and keep tidy.
l Multiple working modes such as volume control and pressure limit, adapt to wide range patient.
l Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime.
l Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects;
l Real time pressure-time, flow-time loop graphics and high precision ETCO
2
,O
2
concentration detection function included.
l Vital sign monitor and Anesthetic gas monitor are optional.
Safety
l Three level alarming system, visual and sound alarm information.
l Intelligent dual system controls ensure safe use in clinics.
l With lots of alarming, reminding and protection functions.
l Advanced power management control technology.
l With built-in backup power source, when outside power source goes off, back-up power source starts to work.
Specifications
Ventilation modes
IPPV; A/C; PCV; SIMV; SIGH
; MAUN
Ventilator parameter ranges
Flow meter
O
2
(0.1-10L/min)
N
2
O(0.1-10L/min)
AIR(0.1-10L/min)
Rapid oxygen supply
35L/min-75L/min
Tidal volume(Vt)
0, 20 mL ~ 1500 mL
Frequence(Freq)
1bpm ~ 100 bpm
I/E
4:1~1:8
PEEP
0cmH2O ~ 30 cmH2O
Pressure triggering sensitivity(PTr)
-20 cmH2O ~ 0 cmH2O(Based on PEEP)
Flow trigger sensitivity (FTr)
0.5 L/min ~ 30 L/min
Pressure control (PC)
5 cmH2O ~ 60 cmH2O
SIGH
0(off) 1/100 ~ 5/100
Apnea Ventilation
OFF,5 s ~ 60 s
Pressure Limit
20 cmH2O ~ 100 cmH2O
Monitored Parameters
Frequence(Freq)
0 /min ~ 100 /min
Tidal volume(Vt)
0 mL ~ 2000 mL
MV
0 L/min ~ 100 L/min
Oxygen concentration
15 % ~ 100 %
Oscillogr
aphs display
P-T(pressure – time)
F-T(flow – time)
P-V loop (pressure – volume loop)
V-T(volume – time )
Size
Wooden case packing size:L 870*W 890*H 1600mm , GW:190KG ;
Anesthesia Machine size:L930*W750*H 1405 mm ,NW:124KG
Alarm and protection
The AC power failure alarm
Power failure or no connection
Internal battery backup low voltage alarm
<11.3±0.3V
No tidal volume
≤5Ml within 6s
High oxygen concentration alarm
Low oxygen concentration alarm
19%-100%
18%-99%
High Airway pressure alarm
Low Airway pressure alarm
High Minute Volume alarm
Low Minute Volume alarm
Continuous Pressure alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
Adult(5L/min-20L/min) Paed(1L/min-15L/min
0-10L/min)
(PEEP+1.5kPa) over 16s
Suffocation warning
5s-60s no spontaneous ventilation
The maximum limited pressure
<12.5 kPa
Fan error
Oxygen deficit
Show on screen
Show on screen
Working conditions
Gas source
O2,N2O,AIR
Pressure
280kPa-600kPa
Voltage
100-240V
Power frequency
50/60Hz
Input power
80VA
Vaporizer
Anesthesia gas
Adjustable scope % (volume percentage)
Halothane
0 ~ 5
Enflurane
0 ~ 5
Isoflurane
0 ~ 5
Sevoflurane
0 ~ 8